Installing Options
42
2
Attaching IEEE 1284 Interface Board Type A
R
CAUTION:
Important
Before handling the 1284 interface board, touch something metal to discharge
static electricity. Static electricity thing damage the 1284 interface board.
Do not subject the 1284 interface board to physical shocks.
A Check the package contains the following:
IEEE 1284 Interface Board Type A
B Turn off the power, and then unplug the power cable.
C Loosen the two screws and remove the cover of the 1284 interface board in-
stallation unit.
The removed cover is not used when installing the 1284 interface board.
Do not touch inside the controller board compartment. Doing so may cause
a machine malfunction or a burn.